Request A Quote

Overview

Waging War on Dust!

MistCannons are the ultimate tool for large-scale dust suppression.  By means of a powerful turbo-fan, they project a plume of finely-atomised water droplets into the air to suppress dust effectively over wide areas, before it disperses into the environment.

Big Throw

MistCannons can propel mist up to 80 linear metres and can swivel almost full circle, meaning maximum ground coverage can be up to 20,000m² from a single location.  They should not be confused with the more traditional rotary atomisers which are commonly used for localised dust and odour suppression—MistCannons play in a different league altogether!

Mobile

MistCannons are built on a robust steel chassis with forklift slots for ease of transport on site.  There is also the option of wheels to facilitate greater mobility on site.

MistCannons require a 3-phase, 400V power supply and a water supply to the MistCannon.  For situations where you haven’t got water available, you might want to check out MistCannon Rover instead.  If you have neither power nor water available, choose MistCannon Integral or MistCannon Ranger.

Tough

Made in Scandinavia and boasting characteristically superior build quality and robustness, MistCannons can cope with the harshest conditions: whether that be aggressive industrial environments or extreme winter weather, MistCannons will weather the storm!

Green

While placing an emphasis on performance and durability, MistCannons are also designed with the environment in mind, having features such as a two-stage water-saving function and an optional built-in silencer. The filtration system also allows the unit to utilise recycled water.

Remote Control

With Health & Safety Regulations tightening up, we can now offer a remote-control option, meaning that each MistCannon can be controlled from a safe distance, such as from inside a vehicle cab, office or control room.

Wide Range of Uses

MistCannons can handle all manner of dust types, from coarse wood chip to ultra-fine incinerator ash. They can also be modified to spray Corgin odour neutralisers for large scale suppression of nuisance odours.

Worldwide

Although our prime target market is the UK & Ireland, we have exported MistCannons to regions as diverse as continental Europe, Africa, the Middle East and the Far East.  This says a lot about the modularity, reliability and popularity of this product.

Hire Fleet

Corgin have a large hire fleet for both long and short term hire, invaluable for temporary dust suppression or emergency needs.  Optional extras may vary on hire units, although most common features, such as remote control, automated oscillation and wheels, are present on most units.

Features & Benefits

Features

Benefits

Finely atomised spray - for effective removal of airborne dust as well as for damping down dusty surfaces

Optional remote control - allows the MistCannon to be operated from a distance, away from the work face

2-stage spray configuration - reduces water consumption

Automatic inlet valve - reduces water consumption

Optional silencer baffle - reduces potential noise nuisance and health issues

Safer for personnel and for the environment

Powerful turbofan & booster pump - allows increased coverage, reducing the need for multiple units

Automated oscillation & tilt - allows increased coverage, reducing the need for multiple units

Throw range of up to 80m - allows increased coverage, reducing the need for multiple units

Forkliftable or wheeled chassis - allows you to relocate the MistCannon easily, also reducing the need for multiple units

Optional dosing pump - allows the MistCannon to be used with odour neutralisers, insecticides or disinfectants

Maximum utilisation of your investment

Optional remote control - allows your operators to control the MistCannon remotely, saving them time and effort

2-stage spray configuration - reduces water consumption costs

Automatic inlet valve - reduces water consumption costs

Lower operating costs

Pump protection - reduces the risk of damage to your pump

Winter kit - reduces the risk of frost damage and allows the MistCannon to be used at low temperatures

Optional automatic drain valve - reduces the risk of frost damage and allows the MistCannon to be used at low temperatures

Reduced downtime & increased reliability

Videos

Specification

The familiar and well-loved D-type MistCannon range has now been superseded by the new A-type range. A-type MistCannons have a number of new and improved design features, as well as better efficiency and lower water output. We still have many D-type MistCannons on our hire fleet, although all new additions to the fleet will now be A-types. All new MistCannons purchased will be A-types.

MistCannon A-type Specifications (for purchase or hire)

Specification

A30

A40

A50

A60

Maximum throw (meters)

30

40

60

80

Total (kW)

7.7

9.7

20.7

32.2

Fan (kW)

5.5

7.5

18.5

30

Pump (kW)

2.2

2.2

2.2

2.2

Full Load Current or FLC (A)

15

20

42

54

Start Up Current (A)

42

84

120

174

Required Electrical Power Connector (400V, 50Hz)

16 A

32 A

63 A

63 A

Suggested Generator Size (kVA)

20

30

60

60

Water output Stage 1: 7 nozzles (Water-saving) (l/m)

20-40

20-40

20-40

20-40

Water output Stage 2: 14 nozzles (Full operation) (l/m)

40-60

40-60

40-60

40-60

Droplet size (microns)

10-150

(mean 70)

10-150

(mean 70)

10-150

(mean 70)

10-150

(mean 70)

Water supply connection

1" BSP male thread (DN25) – normally supplied fitted with QR coupling but can be changed to suit site requirements

Water supply pressure (bar)

2-10

2-10

2-10

2-10

Working pressure (bar)

5-15

5-15

5-15

5-15

Weight (kg)

435

455

515

690

Vertical tilt (degrees)

-10 to +50°

-10 to +50°

-10 to +50°

-10 to +50°

3-point Oscillation (standard option)

Oscillation through either 15°, 30° or 60° from any point across a 330° range

Full Oscillation (optional extra)

Full 330° range with timer function

 

MistCannon D-type Specifications (for hire only)

Specification

D300 Premier

D400 Premier

D600 Premier

D800 Premier

Maximum throw (meters)

30

40

60

80

Total (kW)

7.5

13.5

23.0

34.5

Fan (kW)

5.5

9

18.5

30

Pump (kW)

1.5

4

4

4

Full Load Current or FLC (A)

14

28

40

58

Start Up Current (A)

42

84

120

174

Required Electrical Power Connector (400V, 50Hz)

16 A

32 A

63 A

63 A

Suggested Generator Size (kVA)

18

35

60

60

Water output Stage 1: 6 nozzles (Water-saving) (l/m)

14-20

22-25

22-25

22-25

Water output Stage 2: 20 nozzles (Full operation) (l/m)

44-62

68-77

68-77

68-77

Droplet size (microns)

50-200

(mean 90)

50-200

(mean 90)

50-200

(mean 90)

50-200

(mean 90)

Water supply connection

1" BSP male thread (DN25) – normally supplied fitted with QR coupling but can be changed to suit site requirements

Water supply pressure (bar)

2-10

2-10

2-10

2-10

Working pressure (bar)

9-19

20-30

20-30

20-30

Weight (kg)

415

465

490

600

Vertical tilt (degrees)

0-60°

0-60°

0-60°

0-35°

Oscillation (degrees)

30-330°

30-330°

30-330°

30-330°

The familiar and well-loved D-type MistCannon range has now been superseded by the new A-type range. A-type MistCannons have a number of new and improved design features, as well as better efficiency and lower water output. We still have many D-type MistCannons on our hire fleet, although all new additions to the fleet will now be A-types. All new MistCannons purchased will be A-types.

MistCannon A-type Specifications (for purchase or hire)

Specification

A30

Maximum throw (meters)

30

Total (kW)

7.7

Fan (kW)

5.5

Pump (kW)

2.2

Full Load Current or FLC (A)

15

Start Up Current (A)

42

Required Electrical Power Connector (400V, 50Hz)

16 A

Suggested Generator Size (kVA)

20

Water output Stage 1: 7 nozzles (Water-saving) (l/m)

20-40

Water output Stage 2: 14 nozzles (Full operation) (l/m)

40-60

Droplet size (microns)

10-150

(mean 70)

Water supply connection - 1" BSP male thread (DN25) – normally supplied fitted with QR coupling but can be changed to suit site requirements

Water supply pressure (bar)

2-10

Working pressure (bar)

5-15

Weight (kg)

435

Vertical tilt (degrees)

-10 to +50°

Specification

A40

Maximum throw (meters)

40

Total (kW)

9.7

Fan (kW)

7.5

Pump (kW)

2.2

Full Load Current or FLC (A)

20

Start Up Current (A)

84

Required Electrical Power Connector (400V, 50Hz)

32 A

Suggested Generator Size (kVA)

30

Water output Stage 1: 7 nozzles (Water-saving) (l/m)

20-40

Water output Stage 2: 14 nozzles (Full operation) (l/m)

40-60

Droplet size (microns)

10-150

(mean 70)

Water supply connection - 1" BSP male thread (DN25) – normally supplied fitted with QR coupling but can be changed to suit site requirements

Water supply pressure (bar)

2-10

Working pressure (bar)

5-15

Weight (kg)

455

Vertical tilt (degrees)

-10 to +50°

Specification

A50

Maximum throw (meters)

60

Total (kW)

20.7

Fan (kW)

18.5

Pump (kW)

2.2

Full Load Current or FLC (A)

42

Start Up Current (A)

120

Required Electrical Power Connector (400V, 50Hz)

63 A

Suggested Generator Size (kVA)

60

Water output Stage 1: 7 nozzles (Water-saving) (l/m)

20-40

Water output Stage 2: 14 nozzles (Full operation) (l/m)

40-60

Droplet size (microns)

10-150

(mean 70)

Water supply connection - 1" BSP male thread (DN25) – normally supplied fitted with QR coupling but can be changed to suit site requirements

Water supply pressure (bar)

2-10

Working pressure (bar)

5-15

Weight (kg)

515

Vertical tilt (degrees)

-10 to +50°

Specification

A60

Maximum throw (meters)

80

Total (kW)

32.2

Fan (kW)

30

Pump (kW)

2.2

Full Load Current or FLC (A)

54

Start Up Current (A)

174

Required Electrical Power Connector (400V, 50Hz)

63 A

Suggested Generator Size (kVA)

60

Water output Stage 1: 7 nozzles (Water-saving) (l/m)

20-40

Water output Stage 2: 14 nozzles (Full operation) (l/m)

40-60

Droplet size (microns)

10-150

(mean 70)

Water supply connection - 1" BSP male thread (DN25) – normally supplied fitted with QR coupling but can be changed to suit site requirements

Water supply pressure (bar)

2-10

Working pressure (bar)

5-15

Weight (kg)

690

Vertical tilt (degrees)

-10 to +50°

3-point Oscillation (standard option)

Oscillation through either 15°, 30° or 60° from any point across a 330° range

Full Oscillation (optional extra)

Full 330° range with timer function

 

MistCannon D-type Specifications (for hire only)

Specification

D300 Premier

Maximum throw (meters)

30

Total (kW)

7.5

Fan (kW)

5.5

Pump (kW)

1.5

Full Load Current or FLC (A)

14

Start Up Current (A)

42

Required Electrical Power Connector (400V, 50Hz)

16 A

Suggested Generator Size (kVA)

18

Water output Stage 1: 6 nozzles (Water-saving) (l/m)

14-20

Water output Stage 2: 20 nozzles (Full operation) (l/m)

44-62

Droplet size (microns)

50-200

(mean 90)

Water supply connection - 1" BSP male thread (DN25) – normally supplied fitted with QR coupling but can be changed to suit site requirements

Water supply pressure (bar)

2-10

Working pressure (bar)

9-19

Weight (kg)

415

Vertical tilt (degrees)

0-60°

Oscillation (degrees)

30-330°

Specification

D400 Premier

Maximum throw (meters)

40

Total (kW)

13.5

Fan (kW)

9

Pump (kW)

4

Full Load Current or FLC (A)

28

Start Up Current (A)

84

Required Electrical Power Connector (400V, 50Hz)

32 A

Suggested Generator Size (kVA)

35

Water output Stage 1: 6 nozzles (Water-saving) (l/m)

22-25

Water output Stage 2: 20 nozzles (Full operation) (l/m)

68-77

Droplet size (microns)

50-200

(mean 90)

Water supply connection - 1" BSP male thread (DN25) – normally supplied fitted with QR coupling but can be changed to suit site requirements

Water supply pressure (bar)

2-10

Working pressure (bar)

20-30

Weight (kg)

465

Vertical tilt (degrees)

0-60°

Oscillation (degrees)

30-330°

Specification

D600 Premier

Maximum throw (meters)

60

Total (kW)

23.0

Fan (kW)

18.5

Pump (kW)

4

Full Load Current or FLC (A)

40

Start Up Current (A)

120

Required Electrical Power Connector (400V, 50Hz)

63 A

Suggested Generator Size (kVA)

60

Water output Stage 1: 6 nozzles (Water-saving) (l/m)

22-25

Water output Stage 2: 20 nozzles (Full operation) (l/m)

68-77

Droplet size (microns)

50-200

(mean 90)

Water supply connection - 1" BSP male thread (DN25) – normally supplied fitted with QR coupling but can be changed to suit site requirements

Water supply pressure (bar)

2-10

Working pressure (bar)

20-30

Weight (kg)

490

Vertical tilt (degrees)

0-60°

Oscillation (degrees)

30-330°

Specification

D800 Premier

Maximum throw (meters)

80

Total (kW)

34.5

Fan (kW)

30

Pump (kW)

4

Full Load Current or FLC (A)

58

Start Up Current (A)

174

Required Electrical Power Connector (400V, 50Hz)

63 A

Suggested Generator Size (kVA)

60

Water output Stage 1: 6 nozzles (Water-saving) (l/m)

22-25

Water output Stage 2: 20 nozzles (Full operation) (l/m)

68-77

Droplet size (microns)

50-200

(mean 90)

Water supply connection - 1" BSP male thread (DN25) – normally supplied fitted with QR coupling but can be changed to suit site requirements

Water supply pressure (bar)

2-10

Working pressure (bar)

20-30

Weight (kg)

600

Vertical tilt (degrees)

0-35°

Oscillation (degrees)

30-330°

Applications

Where are MistCannons used?

Why are they selected?

   

Quarries

Remote control operation

Mines

Lower noise emissions

Ports

Low water usage

Steelworks

Rapid deployment from hire fleet

Outdoor Recycling Facilities

Ease of mobility

Demolition Sites

Cooling and evaporation

Construction Sites

 

Bulk Materials Handling

 

Aggregate Handling

 

Waste Handling

 

Energy from Waste Facilities